Effectiveness of STAMMOPUR DR 8 and STAMMOPUR 24 against the corona virus (SARS-CoV-2)

The special celaners STAMMOPUR DR 8 and STAMMOPUR 24 are effective against the corona virus (SARS-CoV-2) and suitable for cleaning and disinfection.

Suitable for preparation for reprocessing with STAMMOPUR DR 8:

- Instruments

Suitable for cleaning and disinfection with STAMMOPUR 24:

- Protective goggles
- Face Shields
- Respiratory masks

STAMMOPUR DR 8

1. STAMMOPUR DR 8 may be used for preparation of instruments in case of contamination with the corona virus (SARS-CoV-2), as it has been expertly proven to be effective.

2. RKI and VAH recommend preparations such as STAMMOPUR DR 8 with the property "limitedly virucidal".

3. The proof of efficacy has already been provided by the classification "limitedly virucidal" and does not require separate testing.

The coronavirus (SARS-CoV-2) is an enveloped virus which, according to the RKI and the VAH, is effectively combated by a "limitedly virucidal" disinfectant.

STAMMOPUR DR 8 is "limitedly virucidal", this property is proven by expert opinions. It is CE-marked and VAH-listed.

STAMMOPUR DR 8 is effective and approved within the scope of the proper reprocessing procedure according to KRINKO for uncritical, semi-critical and critical (A/B) instruments, according to VAH listing.

No independent, expert opinion testing of the preparation for coronavirus (SARS-CoV-2) is required to prove its efficacy, since with the proof of efficacy "limitedly virucidal" the efficacy against this particular coronavirus is already fulfilled.

www.vah-online.de
www.rki.de

Preparation of instruments with STAMMOPUR DR 8

Cleaning and disinfection

Dosage and application times
Application in ultrasonic bath: 2 % - 5 minutes*
Application without ultrasound: 2 % - 30 minutes*

*Approved recommended dosage/exposure time

For further dosages see product information.

STAMMOPUR DR 8 Product Information

STAMMOPUR 24

1. STAMMOPUR 24 may be used to disinfect and clean protective equipment in case of contamination with the corona virus (SARS-CoV-2), as it has been expertly proven to be effective.

2. RKI recommends preparations such as STAMMOPUR 24 with the property "limitedly virucidal" for use against the corona virus.

3. The proof of effectiveness has already been provided by the classification "limitedly virucidal" and does not require separate testing.

4. STAMMOPUR 24 is a preparation according to the Biocide Directive. In addition, it is also approved for cleaning and disinfection of medical devices, CE-marked and VAH-listed.

The coronavirus (SARS-CoV-2) is an enveloped virus which, according to the RKI and the VAH, is effectively combated by a "limitedly virucidal" disinfectant.
For the proof of efficacy, no independent, expert opinion testing of the preparation for the coronavirus (SARS-CoV-2) is required, since with the proof of efficacy "limitedly virucidal" the efficacy against this particular coronavirus is already fulfilled.

www.vah-online.de
www.rki.de

Preparation of protective equipment with STAMMOPUR 24

Protective goggles and face shields are suitable for cleaning and disinfection.

Under no circumstances should a mouth-nose protector be cleaned or disinfected with STAMMOPUR 24 or in an ultrasonic bath. This applies to the classic mouth- nose protector, as well as to FFP masks and self-sewn masks.

Cleaning and disinfection

Protective equipment is made of different materials and qualities, therefore no guarantee can be given for material damage. Test material compatibility in an inconspicuous place before use.

The protective equipment is effectively cleaned and disinfected in an ultrasonic bath. Bacteria and viruses, such as the corona virus, are removed. The protective equipment can be used again immediately after application in the ultrasonic bath and thorough rinsing with water of drinking quality and complete drying.

For cleaning and disinfection without ultrasound, STAMMOPUR 24 can be used effectively in an immersion process. In case of heavy contamination, manual cleaning in an immersion bath with a sponge is recommended. Then leave the material to be cleaned in the solution for 30 minutes.

Dosage and application times:
Application in an ultrasonic bath: 1 % - 15 minutes*
Application without ultrasound: 2 % - 30 minutes*

*Approved recommended dosage/exposure time

For further dosages see product information.

STAMMOPUR 24 Product Information

Preparation of respiratory masks with STAMMOPUR 24

Respiratory protection equipment is considered to be contaminated after each use and can be unnoticed by pathogens (e.g. the corona virus).
To avoid health risks and thus to restore readiness for use, respiratory protection equipment must be cleaned and disinfected after use in accordance with the applicable regulations.

Additional information on ultrasonic application

For further information please refer to our brochure personal protective equipment

Cleaning and disinfection

Dosage and application times
Application in ultrasonic bath: 1 % - 15 minutes*
Application without ultrasound: 2 % - 30 minutes*

*Approved recommended dosage/exposure time

For further dosages see product information.

STAMMOPUR 24 Product Information

 

For cleaning without disinfection TICKOPUR R 33 can be used.